Hydrogenation Feed & Effluent project

Information

Design, manufacturing and installation of ThermFlex heat exchanger for Hydrogenation project in the Coal to Ethylene glycol process

  • Application: Heat exchanger for Hydrogenation Reaction in the Coal to Ethylene glycol process
  • Plant: Inner Mongolia
  • Country: China
  • Customer: ECO
  • Media shell side: Reactor effluent in hydrogen stream
  • Media lamella side: Reactor feed in hydrogen stream
  • Design pressure: 33/33 bar
  • Design temperature: 200/200 ℃
  • Material plate bundle: AISI304
  • Material shell: Q345R+AISI304L

The Challenge

One unit of ThermFlex heat exchanger replaced 3 units of Shell & Tube heat exchanger.

The Solution

The units were delivered and installed in time and the result has been to the full satisfaction of the customer.

We improve the internal and external environment for the benefit of the individual and the nature

At ATHCO Engineering A/S we are very keen on making a difference for the environment. Not only are the majority of our products focused on the recovery of heat in the process industry, which means that our customers will experience a “greener” company profile, but we also comply with the strict rules and regulations of the Danish Labor Authorities, thereby holding our self responsible to the environment.